Description
The Magnum ME-BMK-NS is a battery monitor kit. See the details tab for more information.
- The sole difference between the ME-BMK-NS and the ME-BMK is that the ME-BMK-NS does not come with a shunt. A shunt is required to be installed into the battery system for the monitor to work.
- Acting as a fuel gauge for your batteries, the ME-BMK-NS monitors their state of charge (SOC) and then provides this information in an easy to understand display via the ME-RC remote
- Eliminates unnecessary battery recharging saving on fuel and long-term maintenance costs
- If you already have a magnum inverter / charger and magnum remote the ME-BMK is an easy retrofit
- Works with the NE series, MS series, MS-AE series and RD series
- rAH out (resettable amp hours removed): 0 to 65,535 amp hours, resettable (0.1 AH increments)
- tAH out (total amp hours removed): 0 to 65,535,000 amp hours (0.1 k or 100 AH increments)
- Minimum/maximim DC: 7 to 70 VDC, resettable
- Kit includes: Manual, sense module, DC shunt, twisted pair wire, and communication cable
- Sense wire: Twisted pair -blue & orange, 5' length, 18 AWG wire
- Communication cable: 4-conductor, 10' twisted pair, telephone standard
- Remote requirements: Use with an ME-RC with firmware revision of 2.0 or higher or an ME-ARC (all
- revisions)
- Resistance: 0.1 milliohm (500A at 50mV)
- Continuous current: 410 amperes maximum
- Overload current: Overloads to 500 amps for less than 5 minutes if normally operated
- at less than 300 amps
- Warranty: 1 year
Specifications
Amp Hours In/Out | 32,768 amp hours (1 AH increments) |
Battery Soc | % 0 to 100% (1% increments) |
Communication Cable | 4-conductor, 10' twisted pair, telephone standard |
Dc Amps | 0.1 to 999 (1.0%) |
Dc Volts | 7 to 70 (0.5%) auto voltage detection |
Minimum/Maximum Dc | 7 to 70 VDC, resettable |
Power Draw | < .6 watts |
Remote Requirements | Use with ME-RC with firmware version of 2.0 or higher or an ME-ARC (all revisions) |
Sense Wire | Twisted pair-blue & orange, 5' length, 18 AWG wire |